Dual Input Indicator / Controller with Differential Temperature Measurement |
|

The
differential temperature meter is a versatile dual input indicator/controller.
The touch of a button toggles the display between T1, T2 and
T1-T2. Analog output is optional, and any one of the three
values available can be chosen for this output. Dual 5 Amp
relays give you the tools for on/off alarm or control. The
control outputs can be tied to T1, T2 or T1-T2.
|
INFCDT
/ INFCDR
High
Performance
INFINITY® Series Meters
|
 |
Temperature
Displayed as T1-T2, T1 or T2 |
 |
J,
K, T or J DIN Thermocouple Input, User Selectable |
 |
Optional
Programmable Analog Output |
 |
Optional
Two Form C, 5 Amp Relays, Each Relay Independently Assignable
to T1, T2 or T1-T2 |
 |
One-Touch
Tuning in Proportional Mode |
 |
2,
3 or 4-wire RTD Input (DIN or NIST) |
|
NEWPORT
PRODUCT INFO
|
|
|
•
REQUIRES
ADOBE ACROBAT - HELP
|
|
 | | The user selects either J, K, T or J DIN thermocouple input from the
front panel. The units of measure can be switched between °C and °F
with the front-panel pushbuttons. |
The optional analog output may function as retransmission of temperature
or assigned to Setpoint #1 and used as a proportional control output
(-011 required). Setpoint #1 will still continue to operate as a setpoint,
while the analog output of either 4-20 mA or 0-10 V may be used to
proportionally control an external process.
Industrial
Thermocouples

|
SPECIFICATIONS
Isolation:
Dielectric strength to 2500V transient per 3mm spacing based on EN 61010
for 260 Vrms or DC.
NMR: 60 dB
CMR: 120 dB
Overvoltage: 240 V rms
Display: Red 14-segment LED, 13.8 mm (0.54")
Analog-to-Digital Technique: Dual slope
Internal Resolution: 15 bits
Read Rate: 3/sec
Polarity: Automatic
Accuracy at 25°C: ±0.5°C (after 30 min. warm-up)
Span Tempco: ±50 ppm/°C
Step Response: 1-2 sec
Analog Output: Current or voltage, 0-10 V, 4-20 mA, or 0-20 mA
AC Power
Unit: 115 Vac or 230 Vac ±10%; 50-60 Hz, 8 watts max.
DC Power Unit: 10-32 Vdc or 26-56 Vdc; 7 watts max
Operating Temperature: 0-50°C, (32-122°F), RH 90% at 40°C (non-condensing)
Panel Cutout: 45 x 92 mm 1/8 DIN, (1.77" H x 3.62" W)
Weight: 574 g (1.27 lb)
Input
Ranges
|
Model
|
Input
Type
|
Range
|
|
INFCDT
|
J
K
T
J DIN
|
-210
to 760°C (-346 to 1400°F)
-270 to 1372°C (-454 to 2500°F)
-210 to 400°C (-346 to 752°F)
-200 to 900°C (-328 to 1652°F)
|
|
|
100 ohm Pt RTD; 2, 3 or 4-wire
|
-200
to 850°C (-328 to 1562°F) alpha = 0.00385 or 0.00392
|
To
Order
| Models INFCDT - INFCDR |
|
(*)
|
(*)
|
(*)
|
INFINITY
C Differential Thermocouple Meter |
| - |
- |
- |
INFINITY
C Differential RTD Meter |
| - |
- |
- |
Power
and Display |
|
0
|
- |
- |
115 Vac red |
|
1
|
- |
- |
230
Vac red |
|
2
|
- |
- |
115
Vac Green |
|
3
|
- |
- |
230
Vac green |
|
4
|
- |
- |
10-32
Vdc, red |
|
5
|
- |
- |
10-32
Vdc, green |
|
6
|
- |
- |
26-56
Vdc, red |
|
7
|
- |
- |
26-56
Vdc, green |
| - |
- |
- |
Control
Outputs |
| - |
0
|
- |
No Outputs |
| - |
1
|
- |
Dual
5A form C relay outputs |
| - |
- |
- |
Analog Outputs |
| - |
- |
0
|
No Outputs |
| - |
- |
1
|
Analog
Output |
| - |
- |
2
|
Isolated
Analog Output |
|
|
|
† All dollar amounts on this site are shown in US currency.
Note: Each unit comes complete with operator's manual.
Ordering Example: (1) INFCDT-011A differential thermocouple indicator, 115 Vac power, red LED display, non-isolated analog output and dual 5 A form C SPDT relays = $495
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Base Model
|
| |
Select INFCDT for Thermocouple input INFCDR for RTD input
|
(2)
|
Power and Display
|
| |
Select 0 for 115 Vac power and red LED display 1 for 230 Vac power and red LED display 2 for 115 Vac power and green LED display 3 for 230 Vac power and green LED display 4 for 10-32 Vdc power and red LED display 5 for 10-32 Vdc power and green LED display 6 for 26-56 Vdc power and red LED display 7 for 26-56 Vdc power and green LED display
|
(3)
|
Control and Analog Output(s)
|
| |
Select 00A for base model-no outputs 01A for non-isolated analog output 10A for dual 5 A form C SPDT relays 11A for analog output and dual 5 A form C SPDT relays 12A for isolated analog output and dual 5 A form C SPDT relays
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| |
|
 |
 |
|
|
|
|
Keywords: 1/8 DIN Dual Input Indicator/Controller which can be used for Differential Temperature Measurement
|
Back to top |
|
|