The QUANTA Q9000M is a 4-digit indicator/controller with a
wide choice of output options. It provides 0.1 degree resolution for
100 ohm platinum RTD's with alpha of 0.00385. It is complete with
sensor excitation and break detection. Readout can be in °C or
°F, as selected by plug-in jumpers.
POWER
OPTIONS
Six types
of meter power are available: 120 Vac, 240 Vac, 24 Vac, 5 Vdc, isolated
9-32 Vdc, or isolated 26-56 Vdc.
ANALOG OUTPUT
OPTIONS
A 1 mV/degree (±1 V full-scale) analog output is standard and
is suitable for driving a strip-chart recorder. An additional analog
output can be provided by an optional vertical plug-in board. Available
output signals are 0-5 Vdc, 0-10 Vdc, 0-1 mA (source or sink), and
4-20 mA (source or sink). The top and bottom of each output range
can be scaled to fit a user-selected display span. One advantage in
using the Q9000M as a 4-20 mA transmitter is that the current signal
tracks the display, and hence is linearized.
CONTROL OUTPUT OPTIONS
Additional outputs can be provided by a horizontal upper board.
Available options include single-setpoint control with one 10 A relay,
dual-setpoint control with two 10 A relays, 4-20 mA proportional control
(source or sink), time- proportional 2 A solid-state relay control,
and isolated, parallel BCD output. For additional information, please
refer to the QUANTA, Options, and Mechanical sections.
SPECIFICATIONS
ANALOG INPUT
RTD
type: 100-ohm
platinum with alpha of 0.00385
Calibration:
To
DIN 43760, October 1980
Excitation current: 0.42
mA
Sensor
connection: 2,
3 or 4 wires
Max
lead resistance: 20
ohm for 2, 3 or 4-wire connection
Zero
adjustment: ±5°C
(±9°F)
Overvoltage
protection:
15 Vp
NOISE REJECTION
NMR: 115 dB, 50/60 Hz
CMR: 120 dB
CMV: 1500 Vp per HV test, 354 Vp per IEC spacing
ACCURACY AT 25°C
Zero
tempco (bridge-network error): ±0.05 deg/deg
Span tempco, 10°C to 40°C: ±0.006% of reading/°C
Lead resistance effect
2-wire connection: +2.6°C (4.7°F)/ ohm
3- or 4-wire connection: compensated to 20 ohm max
ANALOG-TO-DIGITAL
CONVERSION
Input
configuration: Differential, bipolar
Technique: Dual-slope, average-value
Polarity: Automatic
Signal integration period: 100 ms
Read rate: 2.5/s
DISPLAY
Type:
7-segment, red LED
Height: 0.56 in (14.2 mm)
Symbols: 8.8.8.8
Decimal-point positions: Three positions selectable
by jumpers behind lens or at connector
0 to 9,999 counts: Normal operation
10,000 to 19,999 counts: Four least-significant digits flash
correct reading
Beyond 19,999 counts: All four digits flash zeros
Sensor-break indication: All four digits flash zeros
POWER
AC voltages: 120, 240 or 24 V ac +10%/15%
AC frequency: 49-440 Hz
DC voltages: 9-32 Vdc, isolated to 300 Vp; 26-56 Vdc, isolated
to 300 Vp; 5 Vdc ±5%, non-isolated
Power consumption: 8 W max
ENVIRONMENTAL
Operating temperature: 0 to 60°C
Storage temperature: 40 to +85°C
Relative humidity: 95% at 40°C (non-condensing)
MECHANICAL
Dimensions: Newport DIN1A (1/8 DIN) case (see Mechanical
section for drawings)
Weight: 17 oz (480 g)
Case material: 94V-0 UL-rated polycarbonate
|
|
|
† All dollar amounts on this site are shown in US currency.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
Part Number Builder |
 |
 |
 |
 |
 |
 |
|
|
|
Option Descriptions
|
|
(1)
|
Display Resolution and Case Style
|
| |
Select 9 for ±9,999 counts (4 digits) 8 for ±9,999 with INFINITY FAMILY BEZEL AND ADAPTER
|
(2)
|
Display Type & Meter Power - LCD
|
| |
Select 0 for LED, 120 Vac (49/440 Hz) (BQ20 or BQ90) 1 for LCD, 120 Vac (49/440 Hz) (BQ21) 2 for LED, 240 Vac (49/440 Hz) (BQ22 or BQ92) 3 for LCD, 240 Vac (49/440 Hz) (BQ23) 4 for LED, 9-32 Vdc (isolated) (BQ24 or BQ94) 5 for LCD, 9-32 Vdc (isolated) (BQ25) 6 for LED, 5 Vdc** (BQ26 or BQ96) 7 for LCD, 5 Vdc** (BQ27) 8 for LED, 24 Vac (BQ28 or BQ98) 9 for LCD, 24 Vac (BQ29) A for LED, 26-56 Vdc (isolated) (BQ2A or BQ9A) B for LCD, 26-56 Vdc (isolated) (BQ2B)
|
(3)
|
Analog Output Adders
|
| |
Select 0 for ±1 or ±2 V recorder output, non-isolated. (standard) 1 for 0-5 Vdc, non-isolated (BA01) 2 for 0-10 Vdc, non-isolated (BA01) 3 for 0-1 mA, source or sink, non-isolated (BA01) 4 for 4-20 mA, source or sink, non-isolated (BA01) 5 for 4-20 mA, sink (high-compliance), non-isolated. (BA02) 6 for 4-20 mA, ISOLATED (BA03)
|
(4)
|
Control Output Adders
|
| |
Select 0 for None 1 for Dual-setpoint 10 A relay. (BDT1) 2 for Proportional 4-20 mA control, source or sink (BDP1) 3 for Time-proportional solid-state 2 A relay plus proportional 4-20 mA control, source or sink. (BDP2) 4 for BCD (isolated, latched, buffered, byte addressable). Includes 50-pin mass-termination connector. (BDD2) 5 for Single-setpoint 10 A relay (BDS1)
|
(5)
|
Signal Conditioning Input Adders
|
| |
Select MDC1 for RTD (Pt 100) input -200.0 to +830.0°C (BSCM) MDF1 for RTD (Pt 100) input -328.0 to +999.9°F (BSCM)
|
(6)
|
Display Color
|
| |
Select Nothing(leave field blank) for Red Display (standard) ,G for Green Display
|
(7)
|
Lens
|
| |
Select Nothing(leave field blank) for Standard Lens (with Newport logo) ,BL for Blank Lens
|
| NOTE: All combinations may not be valid, check spec sheet for valid part numbers. |
| | | | | |
|
 |
 |
|
|
|
|
Keywords: 4-Digit RTD Meter, Transmitter & Controller
|
Back to top |
|
|